GD-3100 High Performance Liquid Chromatography HPLC System,Transformer Oil Furfural Analyzer
Product Description
GD-3100
High Performance Liquid Chromatography HPLC System,Transformer Oil Furfural Analyzer
Why do we need use GD-3100 Gradient High performance liquid chromatography HPLC System in Transformer oil?
GD-3100 High Performance Liquid Chromatography HPLC System,Transformer Oil Furfural Analyzer is adopted to analyze the furfural mass concentration P(C:H02) in transformer oil to diagnose the paper insulation status of transformer equipment. This method can not only clearly determine whether the overheating fault is involved Paper insulation, but also can judge the long-term low temperature and overheating of the internal insulation of the transformer due to oil passages and other reasons, local paper insulation aging, and the life of the old transformer. This method can be used for live sampling and is convenient for detection. It has become an effective means for transformer maintenance. The detection of CsH4O2 in transformer oil has been included in the preventive test procedure.
System Configuration
Isocratic system
High-pressure binary gradient system
Quaternary low-pressure gradient system
ELITE-AAK/AAP amino acid analytical system
Characteristics
1) Classic short stroke,serial pitsons,and multi-stage flow correction ensuring pump performance.
2) Concave surface holographic grating and intelligent power supply for deuterium lamp steadily improving detector functioning.
3) Self-development PID control measure bringing true the accuracy of column oven temperature to 0.1℃.
4) The brand-new S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a variety of HPLC systems.
5) Application of optoelectronic isolation and EMI protection ensuring stable communication.
6) All-round upgraded Chromsoft workstation that is operator-friendly and promotes customer experience.
Configuration Table
1 | P3100 High Pressure Constant Flow Pump | 1) Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments 2) Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) 3) Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa) 4) Maximum pressure: 45 MPa 5) Pressure accuracy: ≤±3.0% 6) Pressure pulsation: ≤0.1 MPa |
2 | UV3100 UV/VIS Detector |
|
3 | Chromsoft Chromatographic Data-processing Workstation |
|
4 | GD-3100 System Kits |
|
5 | S3100 Autosampler (optional) |
|
6 | O3100 Colunm Oven |
|
7 | Pretreatment (optional) |
|