GD-3050 2.5KV 5KV Insulation Resistance Tester
Product Description
GD-3050
2.5KV 5KV Insulation Resistance Tester
1. L terminal socket 2. Display 3. G terminal socket
4. E terminal socket 5. Adjusting knob of high voltage 6. ESC key
7. Temperature and humidity sensor 8. Buzzer 9. UP key
10. DOWN key 11. OK key 12. Contrast ratio knob
13. RST resetting key 14. Power switch 15. Charging interface
16. RS232 serial interface
Main Features
1) Microcomputer control, menu operation, large-screen LCD dot matrix display, and stable performance, and it is the intelligent instrument.
2) With a strong ability to resist the interference, it is applicable to the measurement in an environment with severe electromagnetic interference.
3) It is equipped with 7 voltage output gears, namely 50V, 100V, 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
4) When the high voltage is output, it can be regulated continuously as well.
5) Automatic measurement of R15, R60, R600, automatic calculation of DAR, PI.
6) It has strong load capacity, and the short-circuit current is about 5mA.
7) Measuring range: 0 to 10TΩ, and it can switch the range automatically.
8)The combination of simulation bar pointer and digital display can show the change trend of data and accurate measuring results.
9) The testing time can be displayed at any time, and the buzzer will automatically tweet for reminder at every 15 seconds.
10) After the completion of measuring, it will discharge the high voltage automatically, and the discharging time of high voltage is no more than 30 seconds.
11) It can measure the ambient temperature, air humidity and the date and time of each testing automatically.
12) It can save 60 groups of measuring results, and the data will not be lost for 20 years.
13) It has RS232 serial interface, therefore it can communicate with the computer data.
14) 5 minutes of operation, the system automatically beep prompt shutdown.
15) It has the comprehensive perfect protection function, therefore the operational reliability is high.
Technical Index
1 | Rated testing voltage | 50V, 100V, 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 7 voltage output gear in total |
2 | Upper limit of measuring range | 100GΩ ~ 10TΩ |
3 | Lower limit of measuring range | 0.1MΩ |
4 | Output voltage error | ±5% |
5 | Short-circuit current | Approx. 5mA |
6 | Grade of accuracy | Grade 5.0 |
7 | Basic error of second half measuring range | ±( 5%·Rx + 1d ) |
8 | Basic error of first half measuring range | ±( 10%·Rx + 2d ) |
9 | High voltage display error | ±( 5%·Ux + 1d ) |
10 | Temperature measuring error | ±0.5℃ |
11 | Air humidity measuring error | ±2%RH |
12 | Power supply | 14.8V lithium battery |
13 | Service life of battery after one-time charging | 30 days, 10 times of DAR and 5 times of PI test for each day |
14 | Insulation resistance | > 500 MΩ (between the test line and machine case) |
15 | Voltage resistance | AC10.0kV 50Hz 1min |
16 | Working temperature and humidity | 0℃ ~ + 40℃, < 85%RH |
Our Partner