Anti Interference Transformer Capacitance and Dissipation Factor Test Set
Introduction
GDGS Anti Interference Transformer Capacitance and Dissipation Factor Test Set is used to measure tan delta,capacitance and power factor of transformer or other insulation materials.
The max output voltage is 10kV. 12kV can be customized.
It's touch screen for easy operation.
It can be tested in multiple modes. Such as UST,GST,CVT,GSTg,etc.,
Technical Index
1 | Anti-interference | Frequency conversion |
2 | Power Supply | 220V±10%. (AC127V and AC110V can be customized) |
3 | High output | Voltage output: 0.5KV-10KV,Every 0.1kV |
Precision: 2% | ||
Maximum current: 200mA | ||
Capacity:2000VA | ||
4 | Self-excited power | AC 0V∽50V/15A. 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Automatic double frequency |
5 | Resolving power | tgδ: 0.001% Cx: 0.001pF |
6 | Precision | △tgδ:±(Reading*1.0%+0.040%). △C x :±(Reading*1.0%+1.00PF). |
7 | Measuring range | tgδ:Unlimited |
Cx: 15pF< Cx <300nF 10KV: Cx < 60 nF 5kV: Cx < 150 nF 1kV:Cx < 300 nF | ||
CVT test: Cx < 300 nF | ||
8 | CVT range | 10-10000 |
9 | Accuracy | 0.1% |
10 | Resolving power | 0.01 |
11 | Memory size | The 200 group supports U disk data storage |
Notice for use
1. This instrument can be used only on the power-off equipment;
2. The instrument is equipped with step-up transformer, and please note the insulation of high voltage leads and personal security;
3. This instrument shall be earthed reliably;
4. Should carry out insulation detection to equipment before using this instrument to test equipment;
5. Determine the pressure resisting level of equipment and choose the step-up level of instrument correctly to avoid sparking through the equipment and damaging the instrument before using this instrument to test equipment;
6. Although the associated high voltage cable for the instrument has been detected in factory, it still should be kept far away from human body;
7. The input voltage shall be AC220V±10%, and any excess might affect the test precision; the maximum input voltage shall be AC264V, and any excess would cause permanent damage without warranty; If you need work with AC127V or AC110V,kindly tell us in advance.
8. The printer would have paper jam in printing due to loose coil paper during handling, at this time only need to take out the coil paper, wind it tightly and load it again;
9. The instrument should be kept away from moisture and strenuous vibration;
10. The output zero line should be grounded when the generator supplies power, otherwise erroneous earthing will be prompted.
Accessories
Partners
Contact Us
Contact Person: Christine Gou
Whatsapp/Wechat: +86 15123029885
Mobile: +86 15123029885
E-mail: gold05@hy-industry.com
Skype: christinejinhua@outlook.com
GDGS
Anti Interference Transformer Capacitance and Dissipation Factor Test Set
Introduction
GDGS Anti Interference Transformer Capacitance and Dissipation Factor Test Set is used to measure tan delta,capacitance and power factor of transformer or other insulation materials.
The max output voltage is 10kV. 12kV can be customized.
It's touch screen for easy operation.
It can be tested in multiple modes. Such as UST,GST,CVT,GSTg,etc.,
Technical Index
1 | Anti-interference | Frequency conversion |
2 | Power Supply | 220V±10%. (AC127V and AC110V can be customized) |
3 | High output | Voltage output: 0.5KV-10KV,Every 0.1kV |
Precision: 2% | ||
Maximum current: 200mA | ||
Capacity:2000VA | ||
4 | Self-excited power | AC 0V∽50V/15A. 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Automatic double frequency |
5 | Resolving power | tgδ: 0.001% Cx: 0.001pF |
6 | Precision | △tgδ:±(Reading*1.0%+0.040%). △C x :±(Reading*1.0%+1.00PF). |
7 | Measuring range | tgδ:Unlimited |
Cx: 15pF< Cx <300nF 10KV: Cx < 60 nF 5kV: Cx < 150 nF 1kV:Cx < 300 nF | ||
CVT test: Cx < 300 nF | ||
8 | CVT range | 10-10000 |
9 | Accuracy | 0.1% |
10 | Resolving power | 0.01 |
11 | Memory size | The 200 group supports U disk data storage |
Notice for use
1. This instrument can be used only on the power-off equipment;
2. The instrument is equipped with step-up transformer, and please note the insulation of high voltage leads and personal security;
3. This instrument shall be earthed reliably;
4. Should carry out insulation detection to equipment before using this instrument to test equipment;
5. Determine the pressure resisting level of equipment and choose the step-up level of instrument correctly to avoid sparking through the equipment and damaging the instrument before using this instrument to test equipment;
6. Although the associated high voltage cable for the instrument has been detected in factory, it still should be kept far away from human body;
7. The input voltage shall be AC220V±10%, and any excess might affect the test precision; the maximum input voltage shall be AC264V, and any excess would cause permanent damage without warranty; If you need work with AC127V or AC110V,kindly tell us in advance.
8. The printer would have paper jam in printing due to loose coil paper during handling, at this time only need to take out the coil paper, wind it tightly and load it again;
9. The instrument should be kept away from moisture and strenuous vibration;
10. The output zero line should be grounded when the generator supplies power, otherwise erroneous earthing will be prompted.