GDVA-405 0.02% High Accuracy Current Transformer Tester CT PT Analyzer IEC61869

The GDVA-405 0.02% High Accuracy Current Transformer Tester CT PT Analyzer is a test system for protection and metering CTs according to IEC standards. It can also measure PT. Which can carry all kinds of test items of current transformer testing.
Availability:
Quantity:
  • GDVA-405

  • GOLD

  • 9030849000

GDVA-405 0.02% High Accuracy Current Transformer Tester CT PT Analyzer IEC61869


Introduction for GDVA-405 CT PT Analyzer:


GDVA-405 0.02% High Accuracy Current Transformer Tester CT PT Analyzer is the most complete testing system for various CTs and PTs according to IEC60044-1, IEC60044-2, IEC60044-5,IEC60044-6, IEC61869 and C57.13.


GDVA-405 CT PT Analyzer


Main Test Items for GDVA-405 CT PT Analyzer:


Test items for Current Transformer(CT) Test items for Voltage Transformer(PT)

1) Turn ratio detection

2) Ratio and angle error check

3) Polarity test

4) Excitation characteristic test

5) Secondary winding resistance measurement and secondary burden measurement

6) 5% and 10% error curve measurement

7) Transient characteristics analysis

8) Automatic nameplate inference

9) Knee point voltage/current

10) Accuracy Limit Factor (ALF)

11) Instrument security factor (FS)

12) Secondary time constant (Ts)

13) Remanence coefficient (Kr)

14) Accuracy

15) Saturation and desaturation inductance

16) Knee point electromotive force

17) Limit electromotive force

18) Area factor

19) Iron core analysis and core hysteresis loop measurement

1) Turn ratio measurement

2) Ratio and angle error check

3) Polarity test

4) Excitation characteristic test

5) Primary winding resistance test

6) Secondary winding resistance test

7) Secondary burden measurement


Main Features & Advantages for GDVA-405 Current Transformer Tester:


  • GDVA-405 Current Transformer Tester CT PT Analyzer is suitable for laboratory and field testing. 

  • Which can generates AC of 0-180V and 0.001-5A current to sample CT. 

  • The test accuracy is 0.02%(Typical),0.1%(Guarantee).

  • Which can test all types of CT: M, P, TPY, Bushing CT, GIS CT.etc.

  • All the test items can be completed in one time.

  • The max knee point voltage is 60kV.

  • Compare excitation curves with saved excitation curves in the same window

  • Embedded computer, powerful application software support

  • Ultra-wide measurement range


Parameters for GDVA-405 CT PT Analyzer:


1
Test standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, IEC61869,C57.13
2 Power supply AC220V±10%, 50/60Hz±10%(Support customize to AC127V or AC110V)
3 Voltage output 0.1-180V (AC)
4 Current output 0.001-5A(RMS)
5 Power output 500VA
6 Max.  knee voltage measurement 60KV
7 Current measurement Range

0-10A (automatically change  range in 0.1/0.4/2/10A),

Error: <±0.1%+0.01%FS 

8 Voltage measurement Range

0-200V (automatically change range in 1V/10V/70V/200V).

Error: < ±0.1%+0.01%FS

9 Turns ratio measurement Range 1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
10 Phase measurement   Error:±2min

Resolution: 0.01min

11 Winding resistance measurement range

0-8kΩ (automatically change range in 2 ohm/20 ohm/80 ohm/800 ohm/8 kohm).

Error: < 0.2%RDG+0.02%FS.

Maximum resolution :  0.1mΩ.

12 Temperature measurement -50-100 Celsius degree; error<3 Celsius degree
13 CT Secondary burden range

0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm).

Error:  <0.2%RDG+0.02%FS.

Maximum resolution : 0.001ohm.

14 PT Secondary burden range

0-80kohm (automatically change range in 800ohm/8kohm/80kohm).

Error: <0.2%RDG+0.02%FS

Maximum resolution : 0.1ohm.

15 PT ratio measurement range

1-35000,

1-10000, error<0.1%,

10000-35000, error<0.2%

16 PT ratio error measurement Typical error<0.05%,  Maximum Error<0.1%
17 PT phase angle measurement maximum error < 3min
18 Memory capacity >1000 groups test results
19 Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window


New Feature--Control GDVA-405 Current Transformer Tester by your Laptop (Need customization):


CT PT Analyzer (4)


Our Partners


Partners


Contact us


Contact Person: Christine Gou

Whatsapp/Wechat: +86 15123029885

Mobile: +86 15123029885

E-mail: gold05@hy-industry.com


Previous: 
Next: 
Product Inquiry

QUICK LINK

PRODUCT LIST

CONTACT US

Phone : +86 15123029885
Add : Technical Central Building,Eco &Tech Dep Zone, Nan'an District, Chongqing,China
E-mail : gold05@hy-industry.com
Fax : 0086-23-62940030
Whatsapp : +8615123029885
Wechat : + 8615123029885
Copyright  Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd. All rights reserved. Site Map
公安备案号 50010802002590