Availability: | |
---|---|
Quantity: | |
GDGK-307
CHONGQING GOLD
9030849000
GDGK-307 High Voltage Switch Circuit Breaker Analyzer with Dual Ground
Appearance of Circuit Breaker Analyzer
Menu with Dual ground test interface
With the development of society, people have higher and higher requirements for the safety and reliability of electricity. High-voltage circuit breakers are responsible for the dual tasks of control and protection in power systems, and their performance is directly related to the safe operation of the power system. Mechanical characteristic parameters are one of the important parameters for judging the performance of circuit breakers.
Our company's GDGK-307 Circuit breaker analyzer can accurately measure the mechanical dynamic characteristic parameters of oil-less, high-oil, vacuum, SF6 and other high-voltage circuit breakers of various voltage levels.
Advantages
---GDGK-307 High Voltage Switch Circuit Breaker Analyzer with Dual Ground
3 channels of dual ground(6 channels can be customization): The mechanical characteristics of GIS composite appliances and high-voltage circuit breakers can be measured without opening the grounding switch of the ultra-high voltage switchgear.
12 channels of time measurement input channels, three of which support resistance contacts and time contacts at the same time, 6 channels of completely isolated fracture input, which can detect 4-level series fractures at the same time.
Embedded computer
GDGK-307 Circuit Breaker Analyzer integrates the 100A contact resistance tester function to help customers reduce repeated investment.
Automatic evaluation of circuit breaker status based on test results.
It can automatically generate word documents to facilitate customers' data analysis.
You can also control our GDGK-307 Circuit Breaker Analyzer by your computer(need customization).
Main Test Items
---GDGK-307 High Voltage Switch Circuit Breaker Analyzer with Dual Ground
1) Closing time test, opening time test, time spread between poles test, time spread between units of one pole, bounces etc.
2) Closing speed test, opening speed and average speed test.
3) Measurement of clearance between open contacts, over travel, overshoot travel and total travel.
4) Measurement of closing coil current time curve, opening coil current time curve and the maximum coil current.
5) Dynamic/static contact resistance measurement.
6) Test travel time curve, speed time curve and acceleration time curve.
7) Measurement of pre-insertion resistance value and pre-insertion ion time.
8) Measurement of dynamic resistance curve of circuit breaker fracture.
9) Measurement of dynamic resistance curve of circuit breaker fracture.
10) Vibration test, including vibration fingerprint curve acquisition, management, and vibration fingerprint curve automatic matching.
11) CO-t1-CO,O-t-CO-t1-CO,CO rated operating sequence verification test.
12) Drawing Envelopes for reference travel curve and others.
Technical Index
---GDGK-307 High Voltage Switch Circuit Breaker Analyzer with Dual Ground
12 channels for time measurement (3-channel supports both the time contact and resistance contact time, 6-channel isolated contacts for cascaded unit measurement of pole) | ||
1 | Time measurement | Range: 2000ms Error: < 0.1ms Resolution: 0.01ms |
2 | Sampling frequency | 100-25000Hz |
3 | Travel measurement according to sensor | Linear resistance sensor: Measurement range: 0~1000mm; resolution: 0.01mm; error: <0.5mm Measurement range: 0~300mm; resolution: 0.01mm; error: <0.5mm Measurement range: 0~25mm; resolution: 0.01mm; error: <0.05mm |
Angle resistance sensor: Measurement range: 0~360°; resolution: 0.01°; error: <0.5° | ||
Acceleration sensor: Measurement range: 0~250mm; resolution: 0.1mm; error: <5%RDG+2D | ||
4 | Pre-insertion resistance measurement | Range: 50~7000ohm; Error :<1%RDG+2D |
5 | Dynamic resistance measurement | Test current: 25~100A Measurement error: < 1%RDG+2D |
6 | Contact resistance measurement | Range: 0-10mohm Error <0.5%RDG+0.05%FSRange: 0-2mohm; Error: <0.5%RDG+2D |
7 | Speed measurement | 1000mm linear resistance scale: 0~20m/s; error: <0.5%RDG+2D (Optional) 300mm linear resistance scale: 0~20m/s; error: <0.5%RDG+2D 25mm linear resistance scale: 0~20m/s; error: <0.5%RDG+2D Angle sensor: 0~20m/s; error: <0.5%RDG+2D Acceleration sensor: 0~20m/s; error: <5%RDG+2D |
8 | Coil current measurement | Range: 0~3A~30A; resolution: 0.001A; error: <0.01A |
9 | Number of Roche coils for dual grounding test | 3pcs, length 1.5m, current collection range 0-50A |
10 | Dual grounding time measurement range | 20000ms, resolution 0.01ms, maximum measurement error<0.1ms |
11 | Vibration measurement (Optional) | Range: 0~5000G; error: <5% |
12 | Signal generator | Working voltage AC220V ± 10%, peak output voltage 0-40V, frequency range 100-25000 Hz |
13 | Signal transmission clamp | turn ratio range 0-50, diameter 12cm |
14 | Internal DC power source | Voltage: 30~260V; current:0~20A.Instantaneous 30A, automatically complete the low-voltage action test of the circuit breaker, and measure the action voltage value of the circuit breaker; Automatically complete the low-voltage action test of the circuit breaker. |
15 | Power supply | AC220V±10%; 50Hz/60Hz |
16 | Working environment: temperature | -10~50℃; Humidity: <90% |
Built-in 8G storage memory and 2 USB interface for data export and external keyboard or mouse connection. |
Partners
Contact Us
Contact Person: Christine Gou
Whatsapp/Wechat: +86 15123029885
Mobile: +86 15123029885
E-mail: gold05@hy-industry.com
GDGK-307 High Voltage Switch Circuit Breaker Analyzer with Dual Ground
Appearance of Circuit Breaker Analyzer
Menu with Dual ground test interface
With the development of society, people have higher and higher requirements for the safety and reliability of electricity. High-voltage circuit breakers are responsible for the dual tasks of control and protection in power systems, and their performance is directly related to the safe operation of the power system. Mechanical characteristic parameters are one of the important parameters for judging the performance of circuit breakers.
Our company's GDGK-307 Circuit breaker analyzer can accurately measure the mechanical dynamic characteristic parameters of oil-less, high-oil, vacuum, SF6 and other high-voltage circuit breakers of various voltage levels.
Advantages
---GDGK-307 High Voltage Switch Circuit Breaker Analyzer with Dual Ground
3 channels of dual ground(6 channels can be customization): The mechanical characteristics of GIS composite appliances and high-voltage circuit breakers can be measured without opening the grounding switch of the ultra-high voltage switchgear.
12 channels of time measurement input channels, three of which support resistance contacts and time contacts at the same time, 6 channels of completely isolated fracture input, which can detect 4-level series fractures at the same time.
Embedded computer
GDGK-307 Circuit Breaker Analyzer integrates the 100A contact resistance tester function to help customers reduce repeated investment.
Automatic evaluation of circuit breaker status based on test results.
It can automatically generate word documents to facilitate customers' data analysis.
You can also control our GDGK-307 Circuit Breaker Analyzer by your computer(need customization).
Main Test Items
---GDGK-307 High Voltage Switch Circuit Breaker Analyzer with Dual Ground
1) Closing time test, opening time test, time spread between poles test, time spread between units of one pole, bounces etc.
2) Closing speed test, opening speed and average speed test.
3) Measurement of clearance between open contacts, over travel, overshoot travel and total travel.
4) Measurement of closing coil current time curve, opening coil current time curve and the maximum coil current.
5) Dynamic/static contact resistance measurement.
6) Test travel time curve, speed time curve and acceleration time curve.
7) Measurement of pre-insertion resistance value and pre-insertion ion time.
8) Measurement of dynamic resistance curve of circuit breaker fracture.
9) Measurement of dynamic resistance curve of circuit breaker fracture.
10) Vibration test, including vibration fingerprint curve acquisition, management, and vibration fingerprint curve automatic matching.
11) CO-t1-CO,O-t-CO-t1-CO,CO rated operating sequence verification test.
12) Drawing Envelopes for reference travel curve and others.
Technical Index
---GDGK-307 High Voltage Switch Circuit Breaker Analyzer with Dual Ground
12 channels for time measurement (3-channel supports both the time contact and resistance contact time, 6-channel isolated contacts for cascaded unit measurement of pole) | ||
1 | Time measurement | Range: 2000ms Error: < 0.1ms Resolution: 0.01ms |
2 | Sampling frequency | 100-25000Hz |
3 | Travel measurement according to sensor | Linear resistance sensor: Measurement range: 0~1000mm; resolution: 0.01mm; error: <0.5mm Measurement range: 0~300mm; resolution: 0.01mm; error: <0.5mm Measurement range: 0~25mm; resolution: 0.01mm; error: <0.05mm |
Angle resistance sensor: Measurement range: 0~360°; resolution: 0.01°; error: <0.5° | ||
Acceleration sensor: Measurement range: 0~250mm; resolution: 0.1mm; error: <5%RDG+2D | ||
4 | Pre-insertion resistance measurement | Range: 50~7000ohm; Error :<1%RDG+2D |
5 | Dynamic resistance measurement | Test current: 25~100A Measurement error: < 1%RDG+2D |
6 | Contact resistance measurement | Range: 0-10mohm Error <0.5%RDG+0.05%FSRange: 0-2mohm; Error: <0.5%RDG+2D |
7 | Speed measurement | 1000mm linear resistance scale: 0~20m/s; error: <0.5%RDG+2D (Optional) 300mm linear resistance scale: 0~20m/s; error: <0.5%RDG+2D 25mm linear resistance scale: 0~20m/s; error: <0.5%RDG+2D Angle sensor: 0~20m/s; error: <0.5%RDG+2D Acceleration sensor: 0~20m/s; error: <5%RDG+2D |
8 | Coil current measurement | Range: 0~3A~30A; resolution: 0.001A; error: <0.01A |
9 | Number of Roche coils for dual grounding test | 3pcs, length 1.5m, current collection range 0-50A |
10 | Dual grounding time measurement range | 20000ms, resolution 0.01ms, maximum measurement error<0.1ms |
11 | Vibration measurement (Optional) | Range: 0~5000G; error: <5% |
12 | Signal generator | Working voltage AC220V ± 10%, peak output voltage 0-40V, frequency range 100-25000 Hz |
13 | Signal transmission clamp | turn ratio range 0-50, diameter 12cm |
14 | Internal DC power source | Voltage: 30~260V; current:0~20A.Instantaneous 30A, automatically complete the low-voltage action test of the circuit breaker, and measure the action voltage value of the circuit breaker; Automatically complete the low-voltage action test of the circuit breaker. |
15 | Power supply | AC220V±10%; 50Hz/60Hz |
16 | Working environment: temperature | -10~50℃; Humidity: <90% |
Built-in 8G storage memory and 2 USB interface for data export and external keyboard or mouse connection. |
Partners
Contact Us
Contact Person: Christine Gou
Whatsapp/Wechat: +86 15123029885
Mobile: +86 15123029885
E-mail: gold05@hy-industry.com